{"product_id":"ati-icp-oes-ms-seawater-ro-water-icp-test","title":"ATI ICP-OES\/MS Seawater + RO Water ICP Test","description":"\u003cp class=\"MsoNormal\"\u003eICP-MS Ultimate Seawater Analysis is a combined ICP-OES and ICP-MS analysis for aquarium hobbyists and professionals. With precise measurements from major to ultra-trace elements, ATI ICP-MS Ultimate Laboratory Analysis achieves unmatched accuracy.\u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003eWith ATI ICP-MS Ultimate Lab Analysis, you get the ultimate in accuracy across the board with the combination of ICP-OES and ICP-MS technologies, delivering our most comprehensive analysis. ATI Ultimate Lab Analysis has many benefits:\u003c\/p\u003e\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eIncreased accuracy and significantly lower detection limits down to ultra-trace levels with ICP-MS (e.g. manganese, selenium, vanadium, arsenic, etc.) – elemental detection is possible down to 0.001 µg\/l (compared to ICP-OES detection limits, which range from 0.5 to 3.5 µg\/l depending on the element).\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEarly detection of contaminants enables faster response to prevent potential problems.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDouble-validated results: Many parameters are measured by both ICP-OES and ICP-MS, with cross-checking to ensure consistency and reduce measurement errors.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eExpanded element portfolio (MS* trace elements and MS* contaminants): rubidium, neodymium, zirconium, and many others.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse of the most suitable measurement method for each water parameter – for example, major elements are measured by ICP-OES, while trace and ultra-trace elements are analysed by ICP-MS.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"MsoNormal\"\u003eWith precise measurement from bulk to ultra-trace elements, the ATI Laboratory Analysis ICP-MS Ultimate achieves unprecedented accuracy.\u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\u003ctable style=\"border-collapse: collapse; width: 809px; height: 789px; border-spacing: 0px; border-style: inset; border-color: #000000;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 260px;\" width=\"194\"\u003e\n\u003ccol style=\"width: 186px;\" width=\"146\"\u003e\n\u003ccol style=\"width: 181px;\" width=\"111\"\u003e\n\u003ccol style=\"width: 181px;\" width=\"64\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl63\" style=\"width: 146pt; border-color: #000000;\" width=\"194\" height=\"19\"\u003e\u003cstrong\u003eSetting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-left-style: none; border-color: #000000; width: 109pt;\" width=\"146\"\u003e\u003cstrong\u003eICP-OES Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-left-style: none; border-color: #000000; width: 83pt;\" width=\"111\"\u003e\u003cstrong\u003eICP-OES Pro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-left-style: none; border-color: #000000; width: 48pt;\" width=\"64\"\u003e\u003cstrong\u003eICP-MS Ultimate\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eBulk Elements (except Fluoride)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (high precision)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (high precision)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (high precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eTrace Elements OES\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (average detection limits)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (average detection limits)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓✓ ICP-MS (extremely low detection limits down to ultra-trace levels) and ICP-OES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eOES Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (average detection limits)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (average detection limits)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓✓ ICP-MS (extremely low detection limits down to ultra-trace levels) and ICP-OES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003ePhosphorus\/Phosphate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ High-precision ICP-OES)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ High-precision ICP-OES)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (high precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eNitrate and Fluoride\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ Ion chromatography\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ Ion chromatography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eKH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ Titration\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ Titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eReverse Osmosis Water Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ High-precision ICP-OES)\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓ ICP-OES (high precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eTrace Elements MS*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓✓ ICP-MS (extremely low detection limits down to ultra-trace levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eMS* Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003e✓✓ ICP-MS (extremely low detection limits down to ultra-trace levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\"\u003e\n\u003ctd class=\"xl66\" style=\"border-top-style: none; border-color: #000000;\" height=\"19\"\u003e\u003cstrong\u003eIdeal for:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eBasic analysis for budget-conscious users\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eFull analysis with all key parameters\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top-style: none; border-color: #000000; border-left-style: none;\"\u003eComplete analysis including contaminants and ultra-traces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eThe analysis values in the table include:\u003c\/strong\u003e\u003c\/p\u003e\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSalinity (salt content in the PSU)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eKH (carbonate hardness\/alkalinity)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eNutrients: Nitrogen\/Nitrate, Phosphorus\/Phosphate\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBulk elements: sodium, calcium, chloride, magnesium, sulphur, potassium, bromine, strontium, boron, fluoride\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eTrace elements OES: Barium, Iron, Iodine, Lithium, Molybdenum, Silver, Silicon\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eOES Contaminants: Aluminium, Antimony, Beryllium, Bismuth, Cadmium, Lanthanum, Thallium, Titanium, Tungsten\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eTrace elements MS: * Chromium, Cobalt, Copper, Manganese, Nickel, Rubidium, Selenium, Vanadium, Zinc, Tin\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMS Contaminants: * Arsenic, Lead, Neodymium, Niobium, Zirconium, Indium, Germanium, Gallium, Mercury, Tellurium\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"MsoNormal\"\u003e* Trace elements\/MS contaminants – elements measured only by ICP-MS at very low physiologically active levels.\u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eHow ATI laboratory analyses work:\u003c\/strong\u003e\u003c\/p\u003e\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eRegister at lab.atiaquaristik.com, create an aquarium profile and scan the QR code to activate the analysis. https:\/\/atiaquaristik.com\/en\/?page_id=1386\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eFill your aquarium water into the sample tubes included in the test kit.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eStick the barcodes on the dry tubes and send them to the address on the included card.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eATI will confirm receipt of your sample by email.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eOnce your sample is analysed, you will receive another email with a link to the results and detailed recommendations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":57055182782795,"sku":"765426","price":54.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1033\/7065\/4027\/files\/ati_icp_oes_ms_seawater_ro_water_icp_test.jpg?v=1776429582","url":"https:\/\/krakencorals.co.uk\/products\/ati-icp-oes-ms-seawater-ro-water-icp-test","provider":"Kraken Corals","version":"1.0","type":"link"}